The doseBadge5 is the next generation doseBadge noise dosimeter from Cirrus.

It provides all of the unique features of the original doseBadge such as no controls, cables or displays with a range of new functions and features allowing it to be used for compliance with any occupational noise standard.

Bluetooth® communication to the dBLink App (for Android and iOS) or the doseBadge5 Wand allows the instrument to be configured and controlled without user intervention.

IMeasurements can be scheduled to start, pause and stop automatically with the timer functions allowing the doseBadge5 to be deployed quickly and easily.

Automatic calibration detection and USB download through the doseBadge5 Dock alongside the secure, robust internal microphone and tap sensor help ensure that your noise measurements are as effective as possible.

  • Data download via USB through the 5 Dock/Charger
  • NoiseTools software supplied as standard for reporting & data analysis
  • User configurable ULT triggers for all channels
  • Visual indication of Dose exceedence with user defined levels
  • Fast & Slow time weightings for RMS channels

Specifications

Applicable Standards IEC 61252:1993 +AMD1:2000 Personal Sound Exposure Meters
ANSI S1.25:1991 (R2007) Personal Noise Dosimeters
Measurement Range (Typical)
  • RMS Range: 60dB(A) to 140dB(A)
  • Peak Range: 80dB(C) to 143dB(C) Peak
  • RMS Frequency Weighting: A,C or Z
  • RMS Time Response: None, Fast or Slow
  • Peak Frequency Weighting: A,C or Z
Visual Indication of Status 4 colour LED to show instrument status,
heartbeat and measurement activity
Measurement Functions

The doseBadge5 provides simultaneously the following measurement channels:

  • 4 Simultaneous Independent Integrator Channels
  • 2 Simultaneous Independent Peak Channels
  • Configuration of the integrators and peak channels can be chosen from a preset list, for example ISO (LAeq), ISO (LCeq), OSHA HC, OSHA PEL, ACGIH or user configured as needed.
Overall measurement data Measurement duration
Start time & date
Instrument serial number & name
Calibration information (field & factory calibration)
Overload & Tamper sensor activation
Integrator Channels Measurement Data
Average Integrated Sound Level (Leq/LAVG)
Time Weighted Average (LEP,d/LEX,8/TWA)
Sound Exposure & Estimated Sound Exposure
% Dose & Estimated % Dose
ULT Duration
SPL Max Level & Time
SPL Min Level
Configuration Options Channel namePreset or user defined
Exchange rate: 3, 4 or 5dB
Criterion Level: 80dB to 100dB in 1dB steps
Criterion Time: 1hr to 24hrs in 1hr steps
Threshold Level: None, 70dB to 100dB n 1dB steps
Time Weighting: Fast, Slow or None
Frequency Weighting: A, C or Z
ULT Level: 70dB to 140dB in 1dB steps
ULT Time Weighting: None, Fast or SLow
ULT Frequency Weighting: A,C, or Z
SPL Max Time Weighting: Fast or Slow
SPL Max Freq Weighting: A,C or Z
LED Threshold Trigger: User selectable channel with user selectable % Dose trigger levels
Peak Channels Measurement Data
Time history (Noise Profile): 1 second or 1 minute
Configuration Options
Frequency weighting: A,C or Z
Time history 1 second or 1 minute time history data for each integrator & peak channel (6 channels)
Measurement Control Manual
Manual Start, Stop & Pause via NoiseTools, doseBadge5 Wand or dBLink App
Automatic scheduled measurements
Timed start, pause & stop of measurements
Three timed periods per day
Lunch break pause
Day-by-day control
Shock/Tamper Sensor Internal accelerometer with Off/Low/Medium/High sensitivity settings to detect impact & tampering. Detected impacts marked on time history data
Calibration Automatic detection of external acoustic calibration
User configurable calibration level (typically 114dB or 94dB) for use with 1/2" acoustic calibrators such as the Cirrus CR:514 (94dB) or CR:518 (114dB).
Memory CR:120A doseBadge
Up to 80 hours of Time History Data (6 Channels)
Up to 40 individual measurements
Maximum duration of any single measurement: 24 hours
Power Internal NiMH Battery.
Typical Battery Life >24 hours
Typical 3 hour charge time from empty
CU Series Chargers CU:120A 5 way charger & download dock
Output Wireless communication to doseBadge5 Wand or dBLink App
USB download via CU:120A Dock - Download from all 5 docks simultaneously
Dimensions CR:120A doseBadge
66mm x 43mm x 53mm (excluding clips)
2.53" x 1.69" x 2.01" (excluding clips)
Weight CR:120A doseBadge 85gms (2.9oz)
Temperature -10oC to +50oC Operating
-20oC to +60oC Storage
Humidity
Up to 95% RH Non-Condensing
Software NoiseTools software supplied as standard with license free installation and free of charge upgrades available from the Cirrus website

Resources

General

Applications

The doseBadge can be used in a wide range of different applications. Below are some examples:

  • The measurement and control of occupational noise exposure
  • Compliance with Noise at Work Regulations, Industrial Hygiene Standards and Occupational Noise Exposure Guidelines.
  • Monitoring and recording of long term noise exposure. Noise exposure measurements in Hazardous environments such as Oil Refineries, Petrochemical Plants and Underground Mines.
  • Measurement of noise exposure in the Entertainment and Music Industries.
Top

Make an Enquiry