The doseBadge5 is the next generation doseBadge noise dosimeter from Cirrus.
It provides all of the unique features of the original doseBadge such as no controls, cables or displays with a range of new functions and features allowing it to be used for compliance with any occupational noise standard.
Bluetooth® communication to the dBLink App (for Android and iOS) or the doseBadge5 Wand allows the instrument to be configured and controlled without user intervention.
IMeasurements can be scheduled to start, pause and stop automatically with the timer functions allowing the doseBadge5 to be deployed quickly and easily.
Automatic calibration detection and USB download through the doseBadge5 Dock alongside the secure, robust internal microphone and tap sensor help ensure that your noise measurements are as effective as possible.
Applicable Standards | IEC 61252:1993 +AMD1:2000 Personal Sound Exposure Meters ANSI S1.25:1991 (R2007) Personal Noise Dosimeters |
Measurement Range (Typical) |
|
Visual Indication of Status | 4 colour LED to show instrument status, heartbeat and measurement activity |
Measurement Functions |
The doseBadge5 provides simultaneously the following measurement channels:
|
Overall measurement data | Measurement duration Start time & date Instrument serial number & name Calibration information (field & factory calibration) Overload & Tamper sensor activation |
Integrator Channels | Measurement Data Average Integrated Sound Level (Leq/LAVG) Time Weighted Average (LEP,d/LEX,8/TWA) Sound Exposure & Estimated Sound Exposure % Dose & Estimated % Dose ULT Duration SPL Max Level & Time SPL Min Level |
Configuration Options | Channel namePreset or user defined Exchange rate: 3, 4 or 5dB Criterion Level: 80dB to 100dB in 1dB steps Criterion Time: 1hr to 24hrs in 1hr steps Threshold Level: None, 70dB to 100dB n 1dB steps Time Weighting: Fast, Slow or None Frequency Weighting: A, C or Z ULT Level: 70dB to 140dB in 1dB steps ULT Time Weighting: None, Fast or SLow ULT Frequency Weighting: A,C, or Z SPL Max Time Weighting: Fast or Slow SPL Max Freq Weighting: A,C or Z LED Threshold Trigger: User selectable channel with user selectable % Dose trigger levels |
Peak Channels | Measurement Data Time history (Noise Profile): 1 second or 1 minute Configuration Options Frequency weighting: A,C or Z |
Time history | 1 second or 1 minute time history data for each integrator & peak channel (6 channels) |
Measurement Control | Manual Manual Start, Stop & Pause via NoiseTools, doseBadge5 Wand or dBLink App Automatic scheduled measurements Timed start, pause & stop of measurements Three timed periods per day Lunch break pause Day-by-day control |
Shock/Tamper Sensor | Internal accelerometer with Off/Low/Medium/High sensitivity settings to detect impact & tampering. Detected impacts marked on time history data |
Calibration | Automatic detection of external acoustic calibration User configurable calibration level (typically 114dB or 94dB) for use with 1/2" acoustic calibrators such as the Cirrus CR:514 (94dB) or CR:518 (114dB). |
Memory | CR:120A doseBadge Up to 80 hours of Time History Data (6 Channels) Up to 40 individual measurements Maximum duration of any single measurement: 24 hours |
Power | Internal NiMH Battery. Typical Battery Life >24 hours Typical 3 hour charge time from empty |
CU Series Chargers | CU:120A 5 way charger & download dock |
Output | Wireless communication to doseBadge5 Wand or dBLink App USB download via CU:120A Dock - Download from all 5 docks simultaneously |
Dimensions | CR:120A doseBadge 66mm x 43mm x 53mm (excluding clips) 2.53" x 1.69" x 2.01" (excluding clips) |
Weight | CR:120A doseBadge 85gms (2.9oz) |
Temperature | -10oC to +50oC Operating -20oC to +60oC Storage Humidity Up to 95% RH Non-Condensing |
Software | NoiseTools software supplied as standard with license free installation and free of charge upgrades available from the Cirrus website |
The doseBadge can be used in a wide range of different applications. Below are some examples: