• High sensitivity from 0.2 V/m
  • Isotropic and RMS measurement
  • Excellent attenuation at 50/60 Hz
  • Meets international standards

Specifications

  WPF3 WPF3-HP
High Power version
Frequency range 100 kHz - 3 GHz
Sensor type Isotropic
RMS diode technology
Type of frequency response Flat
Measurament range 0.2 - 130 V/m (CW)
0.2 - 20 V/m (RMS)
0.2 – 1000 V/m (CW)
Dynamic range 52 dB 74 dB
Sensitivity 0.2 V/m
Resolution 0.02 V/m (until 7.5 V/m)
< 2% (starting from 7.5 V/m)
Frequency response (*) ± 1.5 dB (250 kHz – 3 GHz)
- 3 dB (100 kHz)
Linearity ± 0.5 dB (0.5 V/m - 100 V/m)
Isotropic deviation ± 1.2 dB (@ 2 GHz)
Calibration ISO 17025 accredited (ILAC)
Calibration period 24 months (recommended)
Temperature range - 20 ºC to 50 ºC
Temperature response + 0.1 / - 1 dB (related to 20 ºC)
Dimensions 28.4 cm x 6 cm Ø
Weight 95 g
Attenuation at 50/60 Hz Attenuation at 50/60 Hz > 80 dB

(*) The frequency response can be corrected with the SMP2 by using the correction factors stored in the probe (ISO 17025 accredited calibration).

Compatible with SMP2, MonitEM, MapEM

Product specifications and descriptions in this document subject to change without notice

Applications

  • Defence
    assessment of military sites and personnel exposure protection.
  • Labs/R&D
    RF exposure protection of R&D and personnel labs.
  • Industry
    assessment of industrial processes for worker’s exposure protection.
  • Telecommunications
    certification and audit of telecommunication services (GSM, 3G, LTE, TDT, AM, FM, WiFi, etc.).
Top

Make an Enquiry