• Isotropic & True RMS measurement
  • Probe weighted dependent on the selected limit
  • Measurements in accordance with IEC 62110 and IEC 61786

Specifications

Frequency range 10 Hz - 3 kHz
Sensor type Isotropic, RMS
Combined measurement of electric and magnetic field
Type of frequency response 1) Weighted (Results displayed in % of the selected standard)
2) Flat response (Results in V/m, μT, etc. )
Exposure limits(probe in weighted mode) Public and occupational ICNIRP 2010
Customizable to other standards
Measurement range
Weighted mode (ICNIRP 2010)
Field Strength Mode
E-field: 0.025 - 200 of limit (RMS value)
H-field: 0.025 - 200 of limit (RMS value)
E field: 2.5 V/m - 20000 V/m (RMS)
H field: 0.25 μT - 2000 μT (RMS)
Dynamic range 78 dB
Sensitivity Weighted (E,H) 0.025
Flat response E field 2.5 V/m
Flat response H field 0.25 μT
Frequency response ± 20 (typ.) of standard
(25 Hz - 1 kHz)
± 25 (max.)
Linearity ± 1 (typ.) (1 - 100 of standard)
± 2 (max.)
Isotropic response ± 5 (typ.)
Calibration ISO 17025 Accredited Calibration (ILAC)
Calibration period 24 meses (recomendado)
Operating temperature - 15 ºC a 50 ºC
Dimensions 270 mm x 115 mm Ø
Field sensor area 100 cm2
Weight 210 g

Product specifications and descriptions in this document subject to change without notice

Applications

  • Industry
    Measurement in manufacturing facilities with strong electromagnetic fields to ensure workplace safety.
  • Railway
    Measurement of E and H fields generated in trains or near railway facilities.
  • Power grid
    Spot or continuous measurement of E and H at transformer stations and high-voltage lines.