The CV:31A RevoTM Vibration Meter provides a simple and convenient way to measure, analyse and assess vibration data.

Capable of measuring four channels simultaneously, the CV:31A is ideal for assessing hand-arm and whole-body vibration exposure. The instrument can be used to measure whole-body vibration, as well as vibration on passenger and merchant ships.

In addition to the measurement of vibration for human exposure, the CV:31A can also measure three channels of FFT data that can be used to analyse vibration in machinery, vehicles and other vibrating structures. The CV:31A is typically supplied as part of a complete measurement kit, the CK:31HA, which includes the accessories required to carry out Hand-Arm vibration measurements, including handle mounts for the Triaxial accelerometer.

A range of accessories is available including the KD:103 Triaxial Whole Body Seat Accelerometer allowing the CV:31A to be used in a wide range of additional applications.

  • Meets ISO 8041:2005
  • 3 channel FFT for the detection of main frequencies
  • Fourth cannel for SEAT measurements at driver seats
  • 10-14 hours operation with 3 x AA batteries
  • Whole-body vibration measurements to ISO 2631
  • Hand-Arm Vibration Exposure measurements in accordance with ISO 5349:2001, European Directive 2002/44/EC & the Control of Vibration at Work Regulations 2005
  • Vibrations on passenger and merchant ships to ISO 6954
  • SEAT measurement at driver seats with options KD:103 Triaxial Whole Body Seat Accelerometer
  • Condition monitoring of rotating machinery in three axes
  • Vibration measurement in vehicles and other vibrating structures
  • Display of running and interval RMS, maximum RMS (MTVV), Vibration Dose Value (VDV), Vector Sum, Peak and Maximum Peak value

Specifications

Standards ISO 8041
ISO 5349-1:2001
ISO 5349-2:2001
Measurements  
Human Vibration (Acceleration) Interval RMS, vector sum, max. running RMS (MTVV), vibration dose value (VDV)
Acceleration, Velocity & Displacement Running RMS, maximum RMS, vector sum, peak value, maximum peak value
Daily exposure A(8) A(8) calculation for difference activities and test persons via software
Frequency Range  
Acceleration 0.1 - 2000 Hz/1-1000 Hz
Velocity 1-100 Hz/2-1000 Hz/10 - 1000 Hz
Displacement 5-250 Hz
Measurement Range  
Acceleration 800 m/s2
Velocity 100-10000 mm/s
Displacement 250-15000 μm
Linearity Range > 75 dB for ± 6 % error

Applications

  • Hand-Arm Vibration
  • Whole-Body Vibration
  • Machinery Vibration
Top

Make an Enquiry