Q-Trak Indoor Air Quality Monitor

Providing a comfortable, safe and healthy indoor environment is an increasingly important concern. Good air quality increases concentration and productivity. It can also reduce lost days due to absence. TSI's Q-TRAK™ IAQ Monitor provides quick, accurate information to assess key IAQ parameters.

  • Simultaneously displays CO2, CO, temperature and humidity measurements
  • Calculates dew point, wet bulb and percent outside air
  • Large graphic display
  • Displays up to 5 measurements
  • On-screen messages and instructions
  • One instrument with multiple plug-in probe options including VOC’s and air velocity
  • Store up to 39 days of data collected at one-minute log intervals
  • TRAKPRO™ data analysis software provided for data logging, analysis and documenting results

Specifications

Carbon Monoxide (IAQ Probe Model 982)  
Sensor Type Electro-chemical
Range 0 to 500 ppm
Accuracy ±3% of reading or 3 ppm, whichever is greater
Resolution 0.1 ppm
Response Time <60 seconds to 90% step change
   
Carbon Dioxide (IAQ Probe Models 980 and 982)  
Sensor Type Dual-wavelength NDIR (non-dispersive infrared)
Range 0 to 5,000 ppm
Accuracy2 ±3.0% of reading or ±50 ppm, whichever is greater
Resolution 1 ppm
Response Time 20 seconds
   
Temperature (IAQ Probe Models 980 and 982)  
Sensor Type Thermistor
Range 32 to 140°F (0 to 60°C)
Accuracy ±1.0°F (0.6°C)
Resolution 0.1°F (0.1°C)
Response Time 30 seconds (90% of final value, air velocity at 400 ft/min [2 m/s])
   
Relative Humidity (IAQ Probe Models 980 and 982)  
Sensor Type Thin-film capacitive
Range 0 to 95% RH
Accuracy ±3% RH
Resolution 0.1% RH
Response Time 20 seconds (for 63% of final value)
   
% Outside Air: Range 0 to 100%, Resolution 0.1%
   
Barometric Pressure  
Range 20.36 to 36.648 in. Hg (517.15 to 930.87 mm Hg), Accuracy ±2% of reading
   
Operating Temperature: 40 to 113°F (5 to 45°C)
   
Storage Temperature: -4 to 146°F (-20 to 60°C)
   
Logging Capability  
Range Logs up to 56,035 data points with key (4) measured parameters enabled, 38.9 days at 1-minute log intervals
   
Time Constants: 1 sec, 5 sec, 10 sec, 20 sec, 30 sec (user selectable)
Log Intervals: 1 second up to 1 hour (user selectable)
Meter Dimensions: 3.8 in. × 8.3 in. × 2.1 in. (9.7 cm × 21.1 cm × 5.3 cm)
Probe Dimensions: Length 7.0 in. (17.8 cm), Diameter 0.75 in. (1.9 cm)
Weight (with batteries): 0.8 lbs (0.36 kg)
Power Requirements: Four AA-size alkaline batteries or AC adapter, both included

Resources

General

Applications

  • Measure indoor air quality conditions in schools, offices and other indoor environments
  • Maximize thermal comfort for optimum productivity
  • Investigate Sick Building Syndrome and building related illness