The world’s leading, smallest, and lightest handheld radiation detector
The R400 is a logical next generation instrument greatly based on the original identiFINDER. With 15,000+ identiFINDERs deployed worldwide inputs on how to improve this already excellent instrument have been few but valuable. The R400 is the result of taking these inputs and suggestions and adding them to the original instrument. The R400 uses the same algorithms that have proved themselves over many years of superb operation. The housing and three button, one hand operation is also the same. Following is a listing of the features added to make up the R400:
The R400 is able to rapidly detect, quickly locate, accurately measure and precisely identify gamma emitting radionuclides.
The ability to detect gamma sources as well as the presence of neutrons in the radiation field via an optional neutron detector enhances the identiFINDERs capability.
The standard R400 includes a 1.4” (35 mm) diameter x 2” (51 mm) long NaI (Tl) detector plus a GM tube for high gamma dose rate measurements. Instruments are supplied with a carrying holster plus a wrist strap, serial cable, battery pack for rechargeable and non-rechargeable batteries, charging unit and a carrying case with shoulder strap. An optional, sealed 3He neutron detector can be added for neutron detection. The identiFINDER R400 is also available in fully submersible housing. Variations in operating conditions can affect the performance of radio-isotope identification devices (RIID) with scintillation detectors. Changes in temperatures or high count rates can cause measurements to shift impacting the peak positions and the instrument’s ability to ID accurately. The R400 automatically corrects for these changes by calibrating at start up and continuously stabilizing the measure through the use of an small internal source or our patented LED stabilization technique.
Specifications relevant for certain variants only are labeled with the variant.
Detectors
Gamma NaI *(A, B, C, D, E, F, G, H, I, J, K, M) | Crystal size 35mm (1.38in) × 51mm (2.01in) |
Gamma NaI *(L) | Crystal size 23mm (0.91in) × 21mm (0.83in); tungsten shielded |
Neutron 3He Proportional Counter Tube *(B, D, F, I, K) | 15mm (0.59in) × 54mm (2.13in); net: 14mm (0.55in) × 29mm (1.14in); 8atm (8.106bar) |
Gamma (High Dose Rate) | Geiger-Müller detector |
GPS | 12-channel SiRF III receiver |
Calibration
Internal Source *(A, B, H, I, L) | 137Cs; 15nCi (555Bq); Startup time: ≈60s |
Internal Source *(C, D, J, K) | 137Cs; 3nCi (111Bq); Startup time: ≈200s |
External Source *(E, F, G, M) | 40K; Startup time: ≈320s |
Performance
Energy Range (Gamma) | 20keV – 3MeV |
Throughput | >150kcps |
Max. Input Count Rate | 300kcps |
Sensitivity (137Cs) | >500cps per µSv/h |
Corrections | Real-time linearization of gamma spectrum |
Gamma Spectrum | 1024channels; 3MeV |
Dose Rate Range | 0.000µSv/h – 10.00mSv/h |
dto. Scintillator | 0.000µSv/h – 500µSv/h |
dto. Geiger-Müller Detector | 100µSv/h – 10mSv/h |
dto. Overload | 10mSv/h – 1Sv/h |
Dose Range | 0.000µSv – 1Sv |
Neutron Sensitivity *(B, D, F) | 2.6cps/nv |
Stabilization *(A, B, H, I) | Calibration source; ±1% for temperature change rate of |
Stabilization *(C, D, J, K, L) | Calibration source; LED; ±1% for temperature change rate of |
Stabilization *(E, F, G, M) | LED; ±1% for temperature change rate of |
Nuclide Identification | According to ANSI N42.34 |
Typical Resolution *(A, B, C, D, E, F, G, H, I, J, K, L, M) | ≤8% FWHM at 662keV at 20°C (68°F) ambient temperature |
Typical Resolution *(N) | ≤6% FWHM at 662keV at 20°C (68°F) ambient temperature |
Nuclide Library *(A, B, C, D, E, F, H, I, J, K, L, N) | Standard library |
Nuclide Library *(G, M) | Environmental library |
Service
Recommended Interval | 5a |
Dimensions (W × D × H) *(A, B, C, D, E, F, G, L) | 248mm (9.76in) × 93mm (3.66in) × 75mm (2.95in) |
Dimensions (W × D × H) *(H, I, J, K, M) | 270mm (10.63in) × 93.5mm (3.68in) × 82mm (3.23in) |
Weight *(A, C, E, G) | 1180g (41.62oz) including batteries |
Weight *(B, D, F) | 1200g (42.33oz) including batteries |
Weight *(H, J, M) | 1360g (47.97oz) including batteries |
Weight *(I, K) | 1380g (48.68oz) including batteries |
Weight *(L) | 1450g (51.15oz) including batteries |
Housing Material | Aluminium |
Environmental
Operating Temperature | -20°C – +55°C (-4°F – +131°F) |
Storage Temperature | +10°C – +35°C (+50°F – +95°F) |
Temperature Change | Sudden temperature change must not exceed 30.0°C (54.0°F) in order to avoid damage to the detector crystal |
Relative Humidity *(A, B, C, D, E, F, G, L, N) | 10% – 80%, non condensing |
Shock Resistance | According to ANSI N42.34 |
Protection Rating *(A, B, C, D, E, F, G, L, N) | IP53 according to IEC 60529; (with rubber cover mounted on socket) |
Protection Rating *(H, I, J, K, M) | IP68 according to IEC 60529; 10m (32.81ft); 8h |
Battery
Type | FLIR powerPACK ultra 2 (LSD NiMH, rechargeable) |
Capacity | >2000mAh; 4.8V |
Operating Duration | ≥8h at 20°C (68°F) in dose rate mode with dimmed display back light and GPS switched off |
Charging Duration | ≤4h at 20°C (68°F) when instrument off and connected to DC power charger and >4h when powered via USB. |
Quiescent Current | 16.5µA typically |
Display
Type | Transflective color LCD |
Size | 68.4mm (2.69in); 320pixel × 240pixel |
Central Luminance | 400cd/m² typically |
Annunciators | |
Blue LED *(B, D, F, I, K) | Neutron detection and alarm |
Red LED | Gamma alarm |
Amber LED | Charging batteries |
Green LED | External power |
Vibrator | Alarm reporting |
Beeper | Keyboard feedback and alarm reporting |
Memory | |
Data Storage Capacity | 2GB internal memory; 1800MB available for the user |
Identifications incl. Spectrum | ≈600000 |
Data Logging Every 5s *(A, C, E, G, H, J, L, M) | ≈5years |
Data Logging Every 5s *(B, D, F, I, K, N) | ≈2.5years |
Screenshots | ≈2500 |
Alarms | ≈1000000 |
Input/Output | |
USB *(A, B, C, D, E, F, G, L, N) | USB 2.0; micro-B socket |
USB *(H, I, J, K, M) | USB 2.0; LEMO Series K socket with bung |
Bluetooth | Class 2.0; ≤10m (32.81ft) range |
Software | |
Embedded Software | Microsoft Windows CE Operating System |
Web Interface | TCP/IP emulated via USB |
Download File Formats | ANSI N42.42 and spc files compatible with third-party analysis software applications such as GADRAS, Cambio, or PeakEasy |
Reachback | ANSI N42.42 data via Bluetooth to DUN compatible cell phone |
STRIDE Data Protocol | STRIDE Data Protocol for network integration |
Accessories | |
DC Power Adapter, Charger | AC in: 110V – 230V; 50Hz – 60Hz; DC out: 5V; 2A |
Replacement Battery | FLIR powerPACK 2 for 4 AA batteries |
Connection Cable *(A, B, C, D, E, F, G, L, N) | Micro USB-B – USB-A |
Connection Cable *(H, I, J, K, M) | LEMO Series K connector – USB A |
Holster *(A, B, C, D, E, F, G, L, N) | 210g (7.41oz) |
Holster *(H, I, J, K, M) | 220g (7.76oz) |
Carrying Case | Included |
40K Source *(E, F, G, M) | Box with potassium chloride (KCl) |
Environmental Kit *(G) | Smear pad holder; smear pads; disposable gloves; report stationery pad |
Standards | |
ANSI N42.34 | Performance Criteria for Hand-Held Instruments for the Detection and Identification of Radionuclides |
IEC 60529 | Degrees of Protection Provided by Enclosures (IP Code) |
UL 61010-1, Part 1 | Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use, 2005 |
EMC - Directive 2004/108/EC | Regulations concerning electromagnetic compatibility |
ANSI N42.42 2006 | Data format standard for radiation detectors used for Homeland Security |