The SKC AirChek Connect is a Bluetooth-connected, lightweight, quiet sample pump that is simple to use with its intuitive touch screen operation. Connect to mobile device with SmartWave app and to a PC with DataTrac Pro.

Flows from 5 to 5000 ml/min and 5 to 500 ml/min with low flow holder accessory.

  • Compact, lightweight design
  • Ultra-quiet
  • Extended flow range, 5 to 5000 ml/min, suitable for dust sampling and vapour sampling
  • High back pressure compensation- up to 50 inches water at 2 L/min
  • Powerful Li-ion battery for long run times - over 40 hours
  • Bluetooth low energy connectivity for pump operation and monitoring using the SmartWave app
  • Patented* isothermal internal flow sensor
  • Flow fault and auto-restart
  • Large LCD with protective screen cover and screen lock-out feature
  • Displays elapsed time
  • Highly visible pump run and fault status LEDs
  • Tough non-slip anti-static case
  • UL/ATEX approved

* US Patent No. 5,892,160

Specifications

Flow Range Constant flow from 1000 to 5000 ml/min (5 to 500 ml/min requires low flow holder)
Compensation Range (Back Pressure Capability)
  • 5000 ml/min at 20 inches water back pressure
  • 4000 ml/min at 30 inches water back pressure
  • 3000 ml/min at 40 inches water back pressure
  • 2000 ml/min at 50 inches water back pressure
  • 1000 ml/min at 60 inches water back pressure
Power Removable rechargeable lithium-ion (Li-Ion) battery, 7.4 V, 2.6 Ah, 19.2 Wh or AC using cradle
Run Time (Li-Ion)
  • 40+ hours at 2000 ml/min*
  • 15+ hours at 5000 ml/ min*
  • Indefinite run from charging cradle
Accuracy
  • Flow control: ± 5% of set-point after calibration to desired flow
  • Atmospheric pressure: ± 0.3 in Hg
  • Temperature: ± 1.0 C
Display Parameters High-contrast backlit LCD/Time, date, battery status, flow rate, sample volume, temperature, atmospheric pressure, back pressure, programmed run remaining time, and elapsed run time
User Interface Eight-area capacitive touch screen with auto-dim and locking options
Sound Level Average 51.7 dB at 3-ft (1-m) distance using a 37-mm, 0.8-µm MCE filter cassette
Tubing Requires ¼-inch ID tubing
Dimension/Weight 4.1 x 3.7 x 2.8 in (10.4 x 9.4 x 7.1 cm),19.4 oz (550 gm)
Certifications
  • Intrinsic safety (SKC Cat. No. 220-4000 operated with SKC Battery Pack P75718)
  • Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III, T4; Class I, Zone 0
  • AExia IIC T4 Ga; Exia IIC T4 Ga; -20°C ≤ Ta ≤ 45°C; Ex II 1G Exia IIC T4 Ga; IECEx UL 19.0100
  • DEMKO 19ATEX 2288

Resources

Datasheets

Applications

Air quality sampling

Dust monitoring

Vapour sampling

Low flow sampling

Video

Top